Upper & Lower Rehabilitation

EP20M / EP10 System

The wireless EP20M or wired EP10 system includes all the components to make one complete patient evaluation and exercise station for upper and lower extremity rehabilitation.

Includes:

  • (EP20M) Wireless Kit 3 - 1 Wireless Dongle, 3 Wireless Adaptors
  • X4 - InterX Unit
  • Upper Limb Exerciser - Active and active resistive upper extremity exercises of the wrist, forearm, elbow and shoulder
  • Exercise Kit - Myo-EX (whole body EMG for exercise) and AngleX (whole body active exercise against gravity)
  • Hand Kit - Grip and pinch assessment and exercise
  • DFP4 - (4 ForcePlates, 1 BF8 BaseFrame, Connecting leads used when connecting ForcePlates to the X4)
  • Range of Motion Kit - Large and small Goniometers for upper and lower extremity range of motion measurements
  • (EP20M) MyoMeter - Muscle strength testing
  • ESW - Upper extremity evaluation software
  • ICSW - Upper extremity impairment calculation software
  • LSW - lower extremity evaluation and impairment calculation software

Benefits:

  • Typically used in therapy units and educational facilities for hand therapy through to stroke and neuro rehabilitation
  • Suitable for pediatric units through to elderly care
  • Facilitates exercise from a flicker of muscle activity through to full work-hardening exercise for the upper and lower extremities, neck and back
  • Provides weight-bearing balance evaluation combined with innovative exercise
  • Accommodates grip and pinch assessment and exercise
  • ROM measurements are speedily undertaken for upper and lower extremities
  • Generates progress reports for grip, pinch, joint ROM and weight-bearing balance
  • Creates full comprehensive reports, including impairment calculation
  • Facilitates data export for audit and research purposes
  • Wireless elements promote greater portability and ease of use, particularly for upper extremity rehabilitation

Hand Rehabilitation

EP21 / EP11 System

The wireless EP21 or wired EP11 system includes all the components to make one complete upper extremity evaluation and exercise station for hand rehabilitation.

Includes:

  • (EP21) Wireless Kit 3 - 1 Wireless Dongle, 3 Wireless Adaptors
  • (EP11) X4 - InterX Unit
  • Upper Limb Exerciser - Active and active resistive upper extremity exercises of the wrist, forearm, elbow and shoulder
  • Exercise Kit - Myo-EX (whole body EMG for exercise) and AngleX (whole body active exercise against gravity)
  • Hand Kit - Grip and pinch assessment and exercise
  • ForcePlate - For upper extremity weight bearing exercise
  • Range of Motion Kit - Large and small Goniometers for upper and lower extremity range of motion measurements
  • ESW - Upper extremity evaluation software

Benefits:

  • Precise grip and pinch evaluation including standard, sustained and RET tests
  • Accurate, speedy Hand ROM measurements
  • Upper extremity evaluation software documents manually collected test data - for example, sensation testing, MMT
  • Generates full comprehensive reports, including ones to analyze progress over time
  • Data may be simply exported for audit and research purposes
  • Various E-LINK devices facilitate exercise from a flicker of muscle activity – for example, with muscle transfers – through to full work-hardening resistive exercise
  • Desensitization exercise may also be undertaken for pain management programmes
  • Wireless E-LINK promotes greater portability and ease of set up for both hospital clinic and community clinical settings

Stroke & Neuro Rehabilitation

EP24M / EP14 System

The wireless EP24M or EP14 system includes all the components to make one complete evaluation and exercise station for stroke and neuro rehabilitation.

Includes:

  • (EP24M) Wireless Kit 3 - 1 Wireless Dongle, 3 Wireless Adaptors
  • (EP14M) Upper Limb Exerciser - Active and active resistive upper extremity exercises of the wrist, forearm, elbow and shoulder
  • Exercise Kit - Myo-EX (whole body EMG for exercise) and AngleX (whole body active exercise against gravity)
  • Hand Kit - Grip and pinch assessment and exercise
  • (EP24M) MyoMeter - Muscle strength testing
  • X4 - InterX Unit
  • DFP4 - (4 ForcePlates, 1 BF8 BaseFrame, Connecting leads used when connecting ForcePlates to the X4)

Benefits:

  • Suitable for pediatric units through to elderly care
  • Facilitates innovative exercise with immediate biofeedback from a tiny flicker of muscle activity even where there is no visible joint movement
  • Supports progressive, gradable exercise for the upper and lower extremities, neck and back
  • Provides weight-bearing balance evaluation combined with innovative exercise
  • Accommodates grip and pinch assessment and motivating exercise
  • Generates progress reports for grip, pinch and weight-bearing balance assessments
  • Activities also help address perceptual and cognitive issues
  • Data export is included for audit and research purposes
  • Wireless elements promote greater portability, particularly for upper extremity rehabilitation

Physiotherapy Rehabilitation

EP30M System

The wireless EP30M system is an ideal portable system for upper and lower extremity evaluation, typically undertaken by physiotherapists.

Includes:

Benefits:

  • Combines precise grip and pinch assessment with innovative exercise
  • Easily quantifies the force applied during Manual Muscle Testing
  • Includes comprehensive tests for Standard Peak Force, Sustained Force and Grip RET
  • Incorporates data export for audit and research purposes
  • Highly gradable and engaging Activities provide motivational exercise for grip and pinch
  • Wireless elements promote ease of set up and portability
  • Progress reports are quickly generated for outcome measures

Weight-Bearing Rehabilitation

EP40 System

The EP40 Dual-Axis ForcePlate System includes the E-LINK components to make one upper and lower extremity ForcePlate evaluation and exercise station, used widely from orthopedic settings, for sports injuries through to stroke and neuro rehabilitation.

Includes:

  • X4 - InterX Unit
  • DFP4 - (4 ForcePlates, 1 BF8 BaseFrame, Connecting leads used when connecting ForcePlates to the X4)
  • Software - ForcePlate Evaluation and Exercise

Benefits

  • Primarily provides weight-bearing standing balance evaluation and exercise
  • Designed to accurately and objectively assess a patient's ability to maintain postural stability on a static surface
  • Measures fluctuations in the weight distributed over the ForcePlates
  • Results are displayed both in text and graph format for immediate feedback and analysis
  • Evaluates progress over time as an outcome measure
  • Through the innovative integration of computer based Activities the ForcePlates can also be used for interactive exercise
  • Help towards muscle strengthening, neuromuscular re-education and balance co-ordination
  • For additional flexibility the ForcePlates can be removed from the BaseFrame and used with other equipment – gym ball, wobble board, wheelchair
  • Also accommodate evaluation and weight bearing exercise of the upper extremities and for seated balance
  • A single ForcePlate can be used for weight bearing exercise from as little as the touch of one finger through to full weight bearing on one limb
  • Ideal for light touch/short duration exercise in pain management programmes through to full weight loading for strengthening joints and encouraging specific movement patterns